00:00:01
good afternoon, I’m with you again my name is
00:00:04
Lopatin Vladimir Mikhailovich
00:00:06
for ours and of course for those who have subscribed, you
00:00:09
can Mikhalych
00:00:10
today we are removing the settings of an
00:00:13
ultrasonic flaw detector o with d 50
00:00:16
fps company housing for monitoring with an inclined
00:00:22
prismatic transducer,
00:00:26
turning on the flaw detector, as I already told you,
00:00:30
is done with the network two key
00:00:35
hold for three seconds for the
00:00:37
launch to occur; moving through the horizontal
00:00:40
menu is carried out with the left-
00:00:44
right arrows; moving through the vertical menu is
00:00:47
carried out with the up-down arrows;
00:00:51
changing the parameter you candle is
00:00:54
carried out with plus and minus com;
00:00:57
changing the step of this parameter
00:01:01
is carried out with the square key; in
00:01:05
this case, then now we will go through the
00:01:09
correspondence with our algorithm for settings
00:01:13
indicated above in the theoretical part,
00:01:18
so first we must establish the first thing
00:01:22
that we set the speed of
00:01:23
ultrasonic vibrations due to the fact
00:01:26
that we control with you an
00:01:29
inclined transducer, then a
00:01:31
transverse wave will be used to know the
00:01:34
speed of the transverse wave stood up
00:01:37
3,260 we go to the menu in speed
00:01:43
we change the speed to 3,260
00:02:25
installed after that we need to
00:02:31
set the oscillation frequency with you if
00:02:37
you see on the converters it
00:02:39
says frequency two and a half
00:02:41
megahertz the frequency is set in our
00:02:45
generator
00:02:47
move to the generator and set the
00:02:50
frequency to
00:02:52
two and a half megahertz the next thing
00:02:57
we need install this is the
00:02:59
operating diagram of our transducer,
00:03:03
in this case it is a combined
00:03:07
transducer, we move into the sensor,
00:03:11
look at the type of transducer combined
00:03:15
installed next, we must
00:03:18
set the angle of input of ultrasonic
00:03:22
vibrations to the transducers, here it
00:03:24
is indicated with google input 60 degrees,
00:03:27
we go here in the sensor angle and
00:03:30
change it to 60 degrees
00:03:44
the next thing we need to set is to
00:03:47
reset the protector, move
00:03:53
the sensor, change the protector, set it
00:03:57
equal to 0, so we have made
00:04:03
preliminary settings,
00:04:05
then we correspond with our
00:04:08
algorithm, we need to make the settings, the
00:04:12
first thing we set is the
00:04:14
sweep duration,
00:04:17
set the sweep duration
00:04:19
to 7, we control the thickness of the material in
00:04:24
this case we have exactly our sample
00:04:26
is equal to 12 millimeters, which means that
00:04:30
accordingly you and I have to
00:04:32
set the error to 14, in this case
00:04:38
it means 14 multiplied by 7, it turns out 70 and
00:04:47
70 means ninety-four millimeters,
00:04:55
so we go with you to the scan and
00:05:01
set the scan equal to ninety
00:05:04
4 millimeters 98 excuse me the mathematics
00:05:28
was set rather weakly, which means that in the settings you and I are
00:05:32
all with what we use in rc, you and I
00:05:38
had to reset the points in rc,
00:05:41
which means we had to go into vr mode,
00:05:44
which at the points of point 1 and at point 2 we need to
00:05:51
change in rc set equal gain
00:05:56
equal to 0, move in the gain at the
00:06:00
first point 0,
00:06:03
turn on point number 2 and turn on
00:06:07
the gain, also equal to 0, the
00:06:21
next thing we need to set
00:06:24
is we need to set up the depth gauge, as
00:06:28
you remember, the depth gauge is adjusted by
00:06:31
the reflector to a known depth
00:06:36
using our protector,
00:06:40
here we have a charge tank, we
00:06:45
set it in the lower position and
00:06:52
set it up, we catch it on the screen, that is,
00:06:58
we move, we increase the signal amplification
00:07:21
and we earn our earnings. If you pay attention
00:07:24
to the screen, when you move the
00:07:29
transducer across our sample, a
00:07:33
signal appears that
00:07:41
disappears, including here we see
00:07:44
ours on the screen
00:07:47
We amplify the signal, we make sure that it reaches
00:07:53
our strobe and we make sure that the
00:08:01
strobe contains only one of our
00:08:04
useful signals. In this case, on our
00:08:09
tap it still gets into the probing lanyard.
00:08:13
This shouldn’t happen, which means we shift
00:08:15
our beginning so that only one
00:08:20
signal hits, so we on the
00:08:22
screen of the flaw detector we see
00:08:25
that the depth, which is designated by us as y, is
00:08:29
equal to 18 millimeters, and we know that
00:08:34
the sample and the notch in it are at a
00:08:37
depth of 14 millimeters, we move with
00:08:41
you to the sensor and change the protector,
00:08:45
ensuring that the value we have is
00:08:50
14 millimeters,
00:09:05
we see on the screen the depth is 14
00:09:09
millimeters, so we
00:09:11
have set up the depth gauge, the next parameter
00:09:17
that we need to set up is
00:09:20
sensitivity,
00:09:21
what is sensitivity, this is the
00:09:25
minimum size we detect the defect,
00:09:28
sensitivity we set up using
00:09:30
some kind of control reflector, in this
00:09:33
case, for control with an
00:09:36
inclined transducer, we use
00:09:39
a notch
00:09:42
we With you we found a notch with a direct beam,
00:09:47
go into VR mode and install it.
00:09:52
number one and by amplification we ensure that
00:10:04
the signal reaches the rejection level, our
00:10:08
level is set in the zone, or that is, 80
00:10:15
percent of the screen, after that we show the
00:10:24
device where this one is located.
00:10:28
or our notch for this, we move
00:10:32
our marker and combine it with our
00:10:39
reflection on the screen of the flaw detector,
00:10:45
so we see that we have set up the
00:10:48
first point in the rch with you, now we must
00:10:55
turn the sample over and find this
00:11:03
notch with a once reflected beam,
00:11:08
how can we understand whether it is it or not we shift
00:11:12
to one side, we suddenly shift
00:11:15
to the side perpendicular to the direction
00:11:17
along the direction of propagation and
00:11:20
we see our earnings barrel in this case,
00:11:25
here it is on the screen,
00:11:28
which means that there are no unnecessary signals on the screen,
00:11:31
we go into the main mode
00:11:36
and change the scan, reduce it,
00:11:40
we ensure that on the screen We are
00:11:43
left with only the probing signal
00:11:46
reflected from the notch by a once-
00:11:50
reflected beam, so we see on the screen
00:11:54
our zara the barrel has shifted to one
00:11:57
side, shifted to the other side, we have caught
00:11:59
its
00:12:01
maximum,
00:12:13
we have caught its maximum, we go into the grunt mode,
00:12:19
we establish that this is our point number
00:12:23
2 and with time
00:12:29
we show where it is our
00:12:32
point number two is located yes. number
00:12:38
two just coincides with the maximum of
00:12:40
the signal reflected from our notch,
00:12:45
now we go into amplification for the second
00:12:50
point and raise it, ensuring
00:12:54
that the signal reflected from our
00:12:57
notch reaches the level of our
00:13:05
reflector, so we have set up with
00:13:08
you that the sensitivity is the next thing
00:13:16
we need to set is this
00:13:19
control zone the control zone is configured from the
00:13:23
probing signal to the notch on
00:13:26
a single reflection, inclusive,
00:13:30
which means we enter the zones and shift the beginning of the
00:13:39
zone, so it will be sufficiently farther,
00:13:46
move around the screen and ensure that the
00:13:50
signal gets from the notch to the
00:13:54
zone, so we have set up the
00:13:58
control zone, it turns out that we
00:14:02
have completed with you the complete setup of an
00:14:06
ultrasonic flaw detector for
00:14:08
testing with an inclined transducer using
00:14:12
transverse waves, thank you very much if
00:14:20
you liked the video, like and
00:14:23
subscribe
00:14:26
the video is your interest, I will definitely
00:14:28
film other types of setup,
00:14:31
thank you for your attention

Description:

Дефектоскоп. Настройка. Наклонный (призматический) ПЭП.UCD 50 IPS Настройка Наклонный ПЭП. Ультразвуковой контроль.UCD 50 IPS дефектоскоп. Кропус. Применение наклонных, призматических ПЭП. Настройка ВРЧ. Настройка глубиномера

Preparing download options

popular icon
Popular
hd icon
HD video
audio icon
Only sound
total icon
All
* — If the video is playing in a new tab, go to it, then right-click on the video and select "Save video as..."
** — Link intended for online playback in specialized players

Questions about downloading video

mobile menu iconHow can I download "UCD 50 IPS Настройка Наклонный ПЭП" video?mobile menu icon

  • http://unidownloader.com/ website is the best way to download a video or a separate audio track if you want to do without installing programs and extensions.

  • The UDL Helper extension is a convenient button that is seamlessly integrated into YouTube, Instagram and OK.ru sites for fast content download.

  • UDL Client program (for Windows) is the most powerful solution that supports more than 900 websites, social networks and video hosting sites, as well as any video quality that is available in the source.

  • UDL Lite is a really convenient way to access a website from your mobile device. With its help, you can easily download videos directly to your smartphone.

mobile menu iconWhich format of "UCD 50 IPS Настройка Наклонный ПЭП" video should I choose?mobile menu icon

  • The best quality formats are FullHD (1080p), 2K (1440p), 4K (2160p) and 8K (4320p). The higher the resolution of your screen, the higher the video quality should be. However, there are other factors to consider: download speed, amount of free space, and device performance during playback.

mobile menu iconWhy does my computer freeze when loading a "UCD 50 IPS Настройка Наклонный ПЭП" video?mobile menu icon

  • The browser/computer should not freeze completely! If this happens, please report it with a link to the video. Sometimes videos cannot be downloaded directly in a suitable format, so we have added the ability to convert the file to the desired format. In some cases, this process may actively use computer resources.

mobile menu iconHow can I download "UCD 50 IPS Настройка Наклонный ПЭП" video to my phone?mobile menu icon

  • You can download a video to your smartphone using the website or the PWA application UDL Lite. It is also possible to send a download link via QR code using the UDL Helper extension.

mobile menu iconHow can I download an audio track (music) to MP3 "UCD 50 IPS Настройка Наклонный ПЭП"?mobile menu icon

  • The most convenient way is to use the UDL Client program, which supports converting video to MP3 format. In some cases, MP3 can also be downloaded through the UDL Helper extension.

mobile menu iconHow can I save a frame from a video "UCD 50 IPS Настройка Наклонный ПЭП"?mobile menu icon

  • This feature is available in the UDL Helper extension. Make sure that "Show the video snapshot button" is checked in the settings. A camera icon should appear in the lower right corner of the player to the left of the "Settings" icon. When you click on it, the current frame from the video will be saved to your computer in JPEG format.

mobile menu iconWhat's the price of all this stuff?mobile menu icon

  • It costs nothing. Our services are absolutely free for all users. There are no PRO subscriptions, no restrictions on the number or maximum length of downloaded videos.